Product Details
Assay TypeSandwich-ELISA
AnalyteCCL5/RANTES
Format96T
ReactivityHuman
Sensitivity15.63 pg/mL
Standard Curve Range15.63 pg/mL-1000 pg/mL
Assay Time1.75 hr
Suitable Sample TypeFor the quantitative determination of human CCL5/RANTES in Cell Culture Supernatants , Plasma, Serum.
Sample volume50 uL
Materials Provided
IDComponentsSize
CEA088-C01Pre-coated Anti-CCL5 Antibody Microplate1 plate
CEA088-C02Human CCL5 Standard200 μL
CEA088-C03Biotin-Anti-CCL5 Antibody Con. Solution100 μL
CEA088-C04Biotin-Antibody Dilution Buffer8 mL
CEA088-C05Streptavidin-HRP Con. Solution500 μL
CEA088-C06Streptavidin-HRP Dilution Buffer15 mL
CEA088-C0720× Washing Buffer50 mL
CEA088-C082× Sample Dilution Buffer15 mL×2
CEA088-C09Substrate Solution12 mL
CEA088-C10Stop Solution6 mL
  • Background
    ClinMax™ ELISA Kit is convenient ready-to-use immunoassay Kit, specifically designed to quantitate human CCL5 that is present in complex biological samples, such as human serum, plasma, and cell culture supernates.

    A comprehensive validation of the ELISA method was performed following the ICH M10 on bioanalytical method validation and the FDA’s bioanalytical method validation guidance for industry. This validation included assessments of linearity, accuracy, precision, dilution linearity, recovery, and the hook effect. For details information, please refer to the DS.

    ClinMax™ ELISA Kits are manufactured in a GMP-like facility and comply to the ISO 13485 standard, ensuring a high level of quality and reliability.

  • Application

    The kit is developed for quantitative detection of human CCL5 in serum, plasma and cell culture supernates.

    It is for research use only.

  • Storage
    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Typical Data Please refer to DS document for the assay protocol.
 CCL5 TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CCL5/RANTES is less than 15.63 pg/mL.

Validation
Intra-Assay Statistics

Ten replicates of each of 4 samples containing different CCL5/RANTES concentrations were tested in one assay. Acceptable criteria: CV<10%.

 CCL5 INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Five samples containing different concentrations of CCL5/RANTES were tested in independent assays. Acceptable criteria: CV<15%.

 CCL5 INTER-ASSAY STATISTICS
Recovery

Recombinant CCL5/RANTES was spiked into 3 human serum samples, and then analyzed. The average recovery of CCL5/RANTES for serum samples is 92.5%.

 CCL5 RECOVERY
  • Background: CCL5
    Chemokine (C-C motif) ligand 5 (also CCL5) is a protein which in humans is encoded by the CCL5 gene. The gene has been discovered in 1990 by in situ hybridization and it is localized on 17q11. 2-q12 chromosome. It is also known as RANTES (regulated on activation, normal T cell expressed and secreted).
  • Clinical and Translational Updates

Comments (0)


ETA of in-stock products: 2 business days

Price(USD) : $498.00

Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:0 Details
  • Number of Drugs in Clinical Trials:1 Details
  • Latest Research Phase:Phase 2 Clinical

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message