Acrobiosystems for English
icon_bulk_orderBulk inquiry/Quick order
0
There is no goods in the shopping cart !
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: Home > Kits > Endotoxin > RES-A056

Recombinant Factor C Endotoxin Detection Kit

For research use only.

Order Now

  1. Comparable to LAL method - Endpoint fluorescent assay, comparable to other chromogenic quantitative LAL methods.

  2. High specificity - Unlike LAL Assay, as Factor G is absent from the rFC test kit, false-positive results due to β-glucan activation are not expected to occur.

  3. Accuracy - Traceability of endotoxin standards in the kit against USP Standard (Catalog No: 1235503).

  4. Fast time to results - 1 hours.

  5. High sensitivity - Sensitivity range from 0.005-5 EU/mL.

  6. Extensive validation – Verification on multiplex biological products, kinds of microplate readers and various buffer systems, comprehensive validation of specificity, sensitivity, precision, accuracy, applicability, and other aspects according to the parameters listed in the EUROPEAN PHARMACOPOEIA 11.0 and USP chapter<<1225>>.

  7. Sustainable resource - Get rid of dependence on animal derived reagents, reduce dependence on horseshoe crab resources and fishing pressure and realize long-term supply.

  8. Good inter batch consistency - Batch consistency of products is guaranteed due to the use of genetic recombination technology for production.

  • Recombinant C Protein: Saving Horseshoe Crabs for a Greener Future

    Endotoxin PRODUCT Impression

  • Assay Principles
    The Recombinant Factor C Endotoxin Detection Kit is a novel endotoxin detection method based on the recombination technology. Recombinant Factor C, as the first component of the horseshoe crab coagulation cascade reaction, is activated by an endotoxin. The activated Factor C can cleave the fluorogenic substrate and produce a fluorescent signal. The increase of fluorescence signal is positively correlated with the dosage of endotoxin. The experiment is carried on a white 96-well plate and is measured at time zero and after a one-hour 37℃ incubation. Use a fluorescence microplate reader to measure at the wavelength of ex/em = 380/440 nm to determine whether the sample is contaminated by endotoxin.

    Assay Principles

  • Product Details
    Assay TypeFRET
    AnalyteEndotoxin
    Format96T
    Regulatory StatusRUO
    Sensitivity0.005 EU/mL
    Standard Curve Range0.005 EU/mL-5 EU/mL
    Assay Time1 hr
    Suitable Sample TypeFor the quantitative determination of endotoxin from pharmaceutical products, biologicals for injection and some media for tissue cultures.
    Sample volume100 μL
  • Materials Provided
    IDComponentsSize
    RES056-C01Bacterial Endotoxin Standard1 vial
    RES056-C02Recombinant Factor C Protein96 tests
    RES056-C03Fluorogenic Substrate96 tests
    RES056-C04Water for Bacterial Endotoxins Test50 mL
  • Application

    Production process (Process control)

    1. Raw materials

    2. Water testing

    3. Intermediate product testing

    Final product (Release testing)

    1. Parenteral drugs & Biological products

    2. Infusion, injection or tranfusion cells

    3. Cell culture media

    4. Medical devices

    It is for research use only.

  • Storage
    Unopened kit should be stored at 2°C-8°C upon receiving.

    Find the expiration date on the outside packaging and do not use reagents past their expiration date.

Bioactivity-Fluorescence Please refer to DS document for the assay protocol.
 Endotoxin FLUORESCENCE

Take the logarithm of the concentration of the Endotoxin working standard solution as the abscissa, take the ΔRFU as the ordinate. Fitting the standard curve with linearly model, and the correlation coefficient R should be ≥ 0.98 (QC tested).

 Endotoxin FLUORESCENCE

The rFC method was employed to detect endotoxin residues in β-glucan at concentrations of 10ug/mL and 1ug/mL. No non-specific signals were detected. In contrast, the dynamic chromogenic method used for β-glucan detection resulted in the detection of endotoxin and non-specific signals. This indicates that recombinant factor C does not react with β-glucan, demonstrating the good specificity of the rFC method.

  • Clinical and Translational Updates

Comments (0)


ETA of in-stock products: 2 business days

Price(USD) : $348.00

Promotion & Exhibitions



Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message