Product Details
Product Overview
Human Soluble NT5E/CD73 ELISA Kit, PRO is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human NT5E/CD73 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Simplified and straightforward protocols and ready-to-use reagents to save assay time.
Product Specifications
Assay TypeSandwich-ELISAAnalyteSoluble NT5E/CD73Format96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity100 pg/mLAssay Time3 hrSample volume100 μLRange123 pg/mL-30000 pg/mLSample TypeCell Culture Supernatants, Plasma, Serum.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
Application
The kit is developed for quantitative detection of natural and recombinant human NT5E/CD73 in serum, plasma and cell culture supernatants.
It is for research use only.
Workflow

Storage
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Materials Provided
IDComponentsSizeCEA048-C01Pre-coated Anti- Soluble NT5E/CD73 Antibody Microplate1 plateCEA048-C02Human Soluble NT5E/CD73 Standard123μg×2CEA048-C03Biotin-Anti-Soluble NT5E/CD73 Antibody Con. Solution200 μLCEA048-C04Biotin-Antibody Dilution Buffer15 mLCEA048-C05Streptavidin-HRP Con. Solution500 μLCEA048-C06Streptavidin-HRP Dilution Buffer15 mLCEA048-C0720×Washing Buffer50 mLCEA048-C08Sample Dilution Buffer15 mL×2CEA048-C09Substrate Solution12 mLCEA048-C10Stop Solution6 mLACRO Quality Management System
Customers Also Viewed
Performance Data
Typical Data
Please refer to DS document for the assay protocol.

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of NT5E/CD73 is less than 100 pg/mL.
Sample Values
Serum Sample: Thirty-two healthy serum samples (Samples dilution ratio is 1:8) were evaluated for the concentrations of human Soluble NT5E/CD73 in assay.

Intra-Assay Statistics
Ten replicates of each of three samples containing different NT5E/CD73 concentrations were tested in one assay. Acceptable criteria: CV<10%.

Inter-Assay Statistics
Three samples containing different concentrations of NT5E/CD73 were tested in independent assays. Acceptable criteria: CV<15%.

Recovery
Recombinant NT5E/CD73 was spiked into three human serum samples, and then analyzed. The average recovery of NT5E/CD73 for serum samples is 93.0%.

Customer Reviews Writing Reviews

Recent Advances
- English Name:
5'-nucleotidase
- Category:
- Approved Drugs:
0 Details
- Drugs in Clinical Trials:
29 Details
- Highest Development Stage:
Phase 3 Clinical
[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521
















