Product Details
Assay TypeSandwich-ELISA
AnalytebFGF/FGF2
Format96T
ReactivityHuman
Sensitivity7 pg/ml
Standard Curve Range10.94 pg/mL-700 pg/mL
Assay Time2.75 hr
Suitable Sample TypeFor the quantitative determination of human bFGF/FGF2 in Cell Culture Supernatants, Plasma, Serum.
Sample volume50 uL
Materials Provided
IDComponentsSize
CEA082-C01Pre-coated Anti-bFGF/FGF2 Antibody Microplate1 plate
CEA082-C02Human bFGF/FGF2 Standard20μg ×2
CEA082-C03Biotin-Anti-bFGF/FGF2 Antibody Con. Solution100 μL
CEA082-C04Biotin-Antibody Dilution Buffer8 mL
CEA082-C05Streptavidin-HRP Con. Solution500 uL
CEA082-C06Streptavidin-HRP Dilution Buffer15 mL
CEA082-C0720× Washing Buffer50 mL
CEA082-C08Sample Dilution Buffer15 mL ×2
CEA082-C09Substrate Solution12 mL
CEA082-C10Stop Solution6 mL
  • Background
    ClinMax™ ELISA Kit is convenient ready-to-use immunoassay Kit, specifically designed to quantitate human bFGF/FGF2 that is present in complex biological samples, such as human serum, plasma, and cell culture supernates.

    A comprehensive validation of the ELISA method was performed following the ICH M10 on bioanalytical method validation and the FDA’s bioanalytical method validation guidance for industry. This validation included assessments of linearity, accuracy, precision, dilution linearity, recovery, and the hook effect. For details information, please refer to the DS.

    ClinMax™ ELISA Kits are manufactured in a GMP-like facility and comply to the ISO 13485 standard, ensuring a high level of quality and reliability.

  • Application

    The kit is developed for quantitative detection of human bFGF/FGF2 in serum, plasma and cell culture supernates.

    It is for research use only.

  • Storage
    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
  • Assay Principles
     FGF basic Assay Principles
Typical Data Please refer to DS document for the assay protocol.
 FGF basic TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of bFGF/FGF2 is less than 150 pg/mL.

Validation
Intra-Assay Statistics

Ten replicates of each of 3 samples containing different bFGF/FGF2 concentrations were tested in one assay. Acceptable criteria: CV<10%.

 FGF basic INTRA-ASSAY STATISTICS
Inter-Assay Statistics

3 samples containing different concentrations of bFGF/FGF2 were tested in independent assays. Acceptable criteria: CV<15%.

 FGF basic INTER-ASSAY STATISTICS
Recovery

Recombinant bFGF/FGF2 was spiked into 3 human serum samples, and then analyzed. The average recovery of bFGF/FGF2 for serum samples is 100.9%.

 FGF basic RECOVERY
  • Clinical and Translational Updates

Comments (0)


ETA of in-stock products: 2 business days

Price(USD) : $498.00

Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:1 Details
  • Number of Drugs in Clinical Trials:3 Details
  • Latest Research Phase:Approved

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message